Home » Shop » hot sale » Absolute Process Instruments APD 6010 D _ AC to DC transmitter up to 5 A input. Fully isolated.

Absolute Process Instruments APD 6010 D _ AC to DC transmitter up to 5 A input. Fully isolated.

Original price was: $343.20.Current price is: $256.98.

Sale!

44 in stock

SKU: APD 6010 D Category:

Absolute Process Instruments APD 6010 D _ AC to DC transmitter up to 5 A input. Fully isolated.

Cecomp Electronics, APD 6010 D, AC to DC Isolated Signal Conditioner, 9-30 VDC, 10-32 VAC Power

Features:

  • Full 1200 V Input/Output/Power Isolation
  • Zero and Span Output Calibration Potentiometers
  • Input and Output LoopTracker® LEDs
  • Functional Test Button with Remote Capability
  • Built-In Loop Power Supply for Sink/Source Output

Applications:

  • SConvert an AC Signal to a DC Process Signal
  • Monitor Voltage Ranges
  • Convert, Amplify Low Level AC Signals

The APD 6010 D accepts an AC voltage or current input and provides an optically isolated DC voltage or current output that is linearly related to the input. Typical applications include monitoring line, power supply, shunt, and motor voltages or current (either directly or with a current transducer) for control, preventive maintenance, etc.

The full 3-way (input, output, power) isolation makes this module useful for ground loop elimination or noise pickup reduction. The APD 6010 D is factory configured to customer requirements. Consult the factory for assistance with special ranges.

Sink/Source Output Versatility

For maximum versatility a milliamp output can be selectively wired for sinking or sourcing. This allows the APD 6010 D milliamp output to connect to a powered or unpowered current loop. The 20 VDC output loop supply can be used to power a passive mA device if required.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Functional Test

An API exclusive feature includes the Functional Test Button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span.

The functional test button greatly aids in saving time during initial startup and/or troubleshooting. The functional test can also be enabled with a customersupplied external contact closure across terminals 5 and 6. This allows remote testing of the output or, for example, a PLC-controlled manual override setting

Specifications Table:

Input True RMS 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC. Factory configured”specify mVAC, VAC, or mAAC range.
Output 0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-1 mA to 0-20 mADC, 4-20 mADC. Factory configured”specify VDC or mADC range.
AC Input Range Factory configured, please specify input range. Consult factory for special ranges

  • Voltage: 0-50 mVAC to 0-300 VAC
  • Current: 0-1 mAAC to 0-1000 mAAC

Measurements are true RMS

Input Impedance (Voltage Input) 220 kΩ minimum
Input Voltage Burden (Current Input) 1.0 VRMS maximum
Input Frequency 40 Hz to 1000 Hz sinusoidal
Input Protection, Common Mode 750 VDC or 750 VACp
Common Mode Rejection 120 dB minimum
DC Output Ranges Factory configured, please specify input range. Consult factory for special ranges

  • Voltage: 0-1 VDC to 0-10 VDC, 10 mA max
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-1 mADC to 0-20 mADC 20 V compliance, 1000 Ω at 20 mA
Output Calibration Multi-turn zero and span potentiometers (±15% of span adjustment range typical)
Output Loop Power Supply
  • 20 VDC nominal, regulated, 25 mADC
  • Max. ripple, less than 10 mVRMS

May be selectively wired for sinking or sourcing mA output

Output Test/Override Front momentary button or external contact closure sets output to test level. Potentiometer adjustable 0-100% of span.
Output Ripple and Noise Less than 10 mVRMS at 40 Hz and above
Linearity Better than ±0.1% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability
Response Time 150 milliseconds nominal (0-90%)
Isolation
  • 1200 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Housing
  • IP 40, requires installation in panel or enclosure
  • For use in Pollution Degree 2 Environment
  • Mount vertically to a 35 mm DIN rail
Connectors Four 4-terminal removable connectors, 14 AWG max wire size
Power 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum