Home » Shop » hot sale » Absolute Process Instruments APD 6393 _ IsoSplitter1 AC input to 2 DC outputs. Fully isolated.

Absolute Process Instruments APD 6393 _ IsoSplitter1 AC input to 2 DC outputs. Fully isolated.

Original price was: $347.40.Current price is: $179.17.

Sale!

62 in stock

SKU: APD 6393 Category:

Absolute Process Instruments APD 6393 _ IsoSplitter1 AC input to 2 DC outputs. Fully isolated.

Cecomp Electronics, APD 6393, IsoSplitter® AC Signal Splitter 1 AC Input to 2 DC Output, 85-265 VAC, 60-300 VDC Power

Features:

  • One Input to Two Outputs with Full Isolation
  • Zero and Span Output Calibration Potentiometers
  • Full 1200 V Input/Output /Power Isolation
  • Input and Output LoopTracker® LEDs
  • Output Test Button for Each Channel
  • Built-In Loop Power Supplies for Sink/Source I/O

Applications:

  • Split, Convert, Boost, and Rescale Process Signals
  • Split Process Signals for Control and Validation
  • Interface a Process Signal with Multiple Panel Meters, PLCs, Recorders, Data Acq., DCS, & SCADA Systems

The APD 6393 IsoSplitter accepts an AC voltage or current input and provides two optically isolated DC voltage or current outputs that are linearly related to the input. The input range and each output range are independent and can be specified as required. This provides an economical solution when one signal must be sent to two different devices.

Typical applications include isolation, output splitting, output device separation and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these.

The input signal is filtered, amplified, split, and then passed through an opto-coupler to the output stages. Full 4-way isolation (input, output 1, output 2, power) make this module useful for ground loop elimination, common mode signal rejection, and noise pickup reduction.

I/O Sink/Source Versatility

Standard on the APD 6393 is a 15 VDC sensor excitation supply for the input channel and 20 VDC loop excitation supplies for each output channel. These power supplies can be selectively wired for sinking or sourcing allowing use with any combination of powered or unpowered milliamp I/O devices.

LoopTracker

API exclusive features include three LoopTracker LEDs (green for input, red for each output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and troubleshooting.

Output Test

An API exclusive feature includes output test buttons for each channel to provide a fixed output (independent of the input) when held depressed. A test button is provide for each output channel. The output test greatly aids in saving time during initial startup and/or troubleshooting. The test output level for each channel is potentiometer adjustable from 0 to 100% of the output span. Terminals are provided to operate the test functions remotely for each channel. This also allows use as a remote manual override to provide a temporary fixed output if desired.

Specifications Table:

Input True RMS 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC
Output 0-1 V to 0-10 V, ±1 V to ±10 V, 0-1 mA to 20 mA, 4-20 mA
AC Input Range Factory configured, please specify input range

  • Voltage: 0-50 mVAC to 0-300 VAC
  • Current: 0-1 mAAC to 0-1000 mAAC

Measurements are true RMS

Input Impedance (Voltage Input) 220 kΩ minimum
Input Voltage Burden (Current Input) 1.0 VRMS maximum
Input Protection, Common Mode 750 VDC or 750 VACp
Input Frequency 40 Hz to 1000 Hz sinusoidal
Channel 1 and Channel 2 DC Output Ranges Factory configured, please specify for each output channel

  • Voltage: 0-1 VDC to 0-10 VDC, 10 mA max, up to 20 VDC with M19, M29, M39
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-1 mADC to 0-25 mADC, 4-20 mADC, 20 V compliance, 1000 Ω at 20 mA
  • Output offset: ±100% in 15% increments
Output Calibration Multi-turn zero and span potentiometers (±15% of span adjustment range typical)
Output Loop Power Supplies
  • 20 VDC nominal, regulated, 25 mADC for each output channel

May be selectively wired for sinking or sourcing mA output

Output Test/Override Front momentary buttons or external contact closures for each channel to set output test levels. Each output test level potentiometer adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.1% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.04% of span per °C stability
Response Time 70 milliseconds nominal
Isolation Full 4-way, 1200 VRMS minimum
Housing
  • IP 40, requires installation in panel or enclosure with adequate ventilation
  • For use in Pollution Degree 2 Environment
  • Mount vertically (as shown in picture) to a 35 mm DIN rail allowing minimum 1″ (25 mm) above and below housing vents for air circulation
Connectors Eight 4-terminal removable connectors, 14 AWG max wire size
Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum