Home » Shop » hot sale » Absolute Process Instruments API 4058 G _ Bridge, strain gauge, load cell transmitter.Non-isolated.

Absolute Process Instruments API 4058 G _ Bridge, strain gauge, load cell transmitter.Non-isolated.

Original price was: $287.20.Current price is: $174.39.

Sale!

13 in stock

SKU: API 4058 G Category:

Absolute Process Instruments API 4058 G _ Bridge, strain gauge, load cell transmitter. Non-isolated.

Features:

  • Drive up to Four 350 Ω Bridges
  • Adjustable Excitation Power Supply
  • One Minute Setup for Hundreds of I/O Ranges
  • Easy-to-use External Switches for Setup
  • Hot-Swappable Plug-In Design
  • Input and Output LoopTracker® LEDs
  • Output Test or Calibration Resistor Options

Applications:

  • Load Cell Weighing Systems and Scales
  • Strain Gauge Pressure Sensors and Transducers
  • Tanks, Scales, Extruder Melt Pressure, Crane Loads

The API 4058 G accepts a strain gauge, bridge, load cell, or a summed input from up to four sensors, and provides a proportional, non-isolated DC voltage or current output. It includes filtering and processing to allow effective use of lowlevel transducers in the noisy environments found in industrial applications. The output is not electrically isolated.

The built-in 115 mA bridge excitation power supply generates a stable source of excitation voltage to drive from one to four 350 W (or greater) bridge type sensors such as load cells, pressure transducers and strain gauges The API 4058 G amplifies and converts the resulting millivolt signal into the selected output.

Input, output, excitation, and zero offset are field configurable, via external rotary and slide switches. Common ranges are on the module label. An offset switch is standard for applications requiring cancellation of sensor offsets or non-zero deadweights (taring). Zero and span potentiometers allow calibration of the output.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The output test button greatly aids in saving time during initial startup and/or troubleshooting. The test output level is potentiometer adjustable from 0 to 100% of output span. A calibration resistor switch replaces the test button.

Mounting

The API 4058 G plugs into an industry standard 11-Pin octal socket sold separately. Sockets API 011 and finger-safe API 011 FS allow either DIN rail or panel mounting.

Specifications Table:

Input One to Four 350 W Sensors, 0-5 mV to 0-1200 mV, 4-10 VDC Excitation
Output 0-1 V to ±10 V or 0-1 mA to 4-20 mA, Non-Isolated
Strain Gauge Input Range
  • Minimum range: 0 to 5 mV
  • Maximum range: 0 to 1200 mV
  • Minimum sensitivity: 0.5 mV/V
  • Maximum sensitivity: 120 mV/V
  • Millivolt output range is determined by the sensitivity of the sensor (mV/V) and the excitation voltage applied.
  • mV/V sensitivity X excitation voltage = total mV range
Input Impedance 1 MΩ typical
Common Mode Rejection 100 dB minimum
Excitation Voltage
  • Maximum output: 10 VDC maximum at 115 mA
  • Drive capability: Up to four 350 Ω bridges at 10 VDC
  • Switch-selectable: 0-10 VDC in 1 V increments
  • Fine adjustment: ±2.5% via multi-turn potentiometer
  • Stability: ±0.01% per °C
DC Output Ranges
  • Voltage: 0-1 VDC to 0-10 VDC
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-2 mADC to 0-25 mADC 20 V compliance, 1000 W at 20 mA
Output Calibration Multi-turn zero and span potentiometers (±15% of span adjustment range typical)
Zero Offset ±100% of span in 15% increments
Output Test Adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.1% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability
Response Time 150 milliseconds typical 6.6 Hz (Contact factory for faster response times)
Housing and Sockets
  • IP 40, requires installation in panel or enclosure
  • Plugs into API 011 or API 011 FS socket
  • Socket mounts to 35 mm DIN rail or can be surface mounted
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max