Absolute Process Instruments API 4400 G _ Fully isolated. Inputs share

Cecomp Electronics, API 4400 G, Isolated DC to DC Math Function Transmitter, (A+B+C+D)/4

Features:

  • Factory Set Custom I/O Ranges
  • Easy-to-Install Plug-In Design
  • Full 2000 V Input/Output/Power Isolation
  • Input and Output LoopTracker® LEDs
  • Output Test Button

Applications:

  • Add, Subtract, Average Flow Signals
  • Average Multiple Signals

The API 4400 G are factory configured to accept two to four DC voltage or current inputs and provide an optically isolated DC voltage or current output that is proportional to the sum, average and/or difference of the inputs depending on the model.

The A, B, C and D inputs should be the same type, and mixed input ranges are allowable. Consult the factory when selecting mixed input ranges.

Inputs are converted to a percentage and then the math function is applied. Consult the factory if true voltage math is required.

The API 4400 G uses no transformers or choppers in the signal path for best noise immunity and freedom from AC artifacts in the output. The inputs are not isolated from each other and use the same signal common connection. The modules do features full 3-way (input, output, power supply) isolation.

Common ranges as well as custom ranges are possible.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the Functional Test Button to provide a fixed output (independent of the input) when held depressed. The output test level is adjustable from 0 to 100% of output span. The functional test button greatly aids in saving time during initial startup and/or troubleshooting.

Installation

The API 4400 G plug into an industry standard 11-Pin octal socket sold separately. Sockets API 011 and finger-safe API 011 FS allow either DIN rail or panel mounting. The plug-in design, 3-way isolation, and robust electronics allows the module to be quickly hot-swapped without removing the power or I/O signals.

Specifications Table:

Function (A + B + C + D) / 4
DC Input Ranges Factory configured, please specify 4 input ranges.

  • Voltage: 0-100 mVDC to 0-10 VDC
  • Bipolar voltage: ±100 mVDC to ±10 VDC
  • Current: 0-1 mADC to 0-20 mADC, 4-20 mA
  • Popular ranges: 0-1 VDC, 0-5 VDC, 1-5 VDC, 0-10 VDC, ±5 VDC, ±10 VDC, 0-20 mA, 4-20 mA

System voltages must not exceed socket voltage rating Inputs are converted to a percentage and then the math function is applied. Consult factory for mixed ranges, special ranges or non-standard functions.

Input Impedance
  • Voltage: 100 kΩ per volt nominal
  • Current: 50 Ω nominal
Input Voltage Burden (Current) 1.0 VRMS maximum
Balance Between Inputs Better than ±0.5% of span
Input Loop Power Supply 20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMS
DC Output Range Factory configured, please specify output range or consult factory. See table on other side for common ranges.

  • Voltage, 10 mA max.: 0-1 VDC to 0-10 VDC
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-1 mADC to 0-20 mADC, 20 V compliance, 1000 Ω at 20 mA
Output Calibration Multi-turn zero and span potentiometers for output (±15% of span adjustment range typical)
Output Loop Power Supply 20 VDC nominal, regulated, 25 mADC, max. ripple <10 mVRMS
Output Test Sets output to test level when pressed Adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS
Linearity Better than ±0.1% of span
Response Time 70 milliseconds typical
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability, calculated, not tested
Isolation
  • 2000 VRMS minimum
  • Full isolation: power to input, power to output, input to output Individual inputs are single-ended (common ground)
Housing and Sockets
  • IP 40, requires installation in panel or enclosure
  • API 011 or API 011 FS socket
  • Socket mounts to 35 mm DIN rail or can be surface mounted
Power 115 VAC ±10%, 50/60 Hz, 2.5 W max