Home » Shop » hot sale » Absolute Process Instruments API APD 7580 D _ Field Ranged Frequency to Analog Process Signal Isolated Transmitter, 4-20 mA Input, 9-30 VDC Power

Absolute Process Instruments API APD 7580 D _ Field Ranged Frequency to Analog Process Signal Isolated Transmitter, 4-20 mA Input, 9-30 VDC Power

Original price was: $351.20.Current price is: $275.36.

Sale!

22 in stock

SKU: APD 7580 D Category:

Absolute Process Instruments API APD 7580 D _ Field Ranged Frequency to Analog Process Signal Isolated Transmitter, 4-20 mA Input, 9-30 VDC Power

Cecomp Electronics, APD 7580 D, Frequency to DC Isolated Signal Conditioner, 16 Configurable Outputs, 9-30 VDC, 10-32 VAC Power

Features:

  • 1 Minute Setup for 30 Input & 18 Output Ranges
  • External Switches & Tables for Range Selection
  • Zero and Span Output Calibration Potentiometers
  • Full 1200 V Input/Output/Power Isolation
  • Input and Output LoopTracker® LEDs
  • Output Test Button
  • Built-In Loop Power Supply for Sink/Source Output

Applications:

  • Monitor and Control Motor or Line Speed
  • Convert Speed and Frequency Signals

The APD 7580 D accepts a frequency input and provides an optically isolated DC voltage or current output that is linearly related to the input.

Common applications include frequency to DC conversions from frequency output type devices such as rotary encoders, magnetic pick-ups, proximity sensors, variable speed drives, and flow meters. For PLCs that do not have analog outputs, often the pulse rate of a discreet output can be programmed to vary. By connecting the APD 7580 D to this output, a proportional analog signal can be generated. A 15 VDC power supply is provided to power the sensor input, if required.

Full 3-way isolation (input, output, power) makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

The APD 7580 D input and output can be field-configured via external rotary and slide switches. Common ranges are on the module label. Many additional combinations are possible. Consult the factory for assistance with special ranges.

Sink/Source Versatility

For maximum versatility the output can be selectively wired for sinking (unpowered) or sourcing (powered) milliamp output. The 20 VDC loop excitation supply can be used to power a milliamp current loop if required. The output can also be wired for an externally powered loop.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span. The output test button greatly aids in saving time during initial startup and/or troubleshooting.

Specifications Table:

Input Field configurable 0-100 Hz to 0-30 kHz
Outputs Field configurable voltage or milliamp ranges (0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-2 mA to 20 mADC)
Frequency Input Ranges
  • 0-100 Hz to 0-30 kHz, 30 switch selectable input ranges
  • Minimum pulse width 5 µsec
Input Impedance
  • 10 kΩ nominal (maximum sensitivity)
  • 100 kΩ nominal (minimum sensitivity)
Input Sensitivity/Hysteresis Multi-turn potentiometer for sensitivity adjustment

  • Maximum sensitivity: ±25 mV typical
  • Minimum sensitivity: ±2.5 V typica
Input Amplitude Range
  • 100 mV to 150 VRMS
  • Any waveform with minimum 100 mV amplitude change
Input Power Supply
  • 15 VDC ±10%, regulated, 25 mADC
  • Max. ripple, less than 10 mVRMS
  • May be used to power sensor
DC Output Ranges Switch selectable, field rangeable

  • Voltage: 0-1 VDC to 0-10 VDC, 10 mA max
  • Bipolar voltage: ±1 VDC to ±10 VDC
  • Current: 0-2 mADC to 0-20 mADC 20 V compliance, 1000 Ω at 20 mA
Output Calibration Multi-turn zero and span potentiometers

  • ±15% of zero adjustment
  • ±10% of span adjustment typical
Output Loop Power Supply
  • 20 VDC nominal, regulated, 25 mADC
  • Max. ripple, less than 10 mVRMS
  • May be selectively wired for sinking or sourcing mA output
Output Test Front momentary button sets output to test level. Potentiometer adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS ripple and noise
Linearity Better than ±0.8% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability
Isolation
  • 1200 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Installation Environment
  • IP 40, requires installation in panel or enclosure
  • For use in Pollution Degree 2 Environment
  • Mount vertically to a 35 mm DIN rail
Connectors Four 4-terminal removable connectors, 14 AWG max wire size
Power 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum