Absolute Process Instruments T16ADA12S _ transmitter. Fully isolated.
Cecomp Electronics, T16ADA12S, ThermoPro® Temperature Alarm, 12″ Length Spring-Loaded for Thermowell Probe
Features:
- 100 Ω Platinum RTD
- 316 Stainless Steel Probe
- Programmable SPDT Relays
- -58.0°F to 392.0°F or -50.0°C to 200.0°C
- NEMA 4X Housing
- Spring-Loaded Versions for Thermowells
- User-programmable setpoints
- User configurable relay operation
- Pass code protected setup and calibration
Specifications Table:
| Range |
58.0 to 392.0°F or 50.0 to 200.0°C, selectable |
| Resolution |
0.1 degree resolution |
| Typical Accuracy |
Includes linearity error and ±1 LSD 11-point linearization
- ±0.7°C at 50°C
- ±0.4°C at 0°C
- ±0.9°C at 100°C
- ±1.4°C at 200°C
|
| Display |
- 4 readings per second nominal display update rate
- 4 digit LCD, 0.5″ H
- 5 character 0.25″ H alphanumeric
- Low battery voltage indication(ALARM1 under range indication on display, ALARM2 over range indication on display)
|
| Sensor |
- IEC-751 Class B 100 Ω Platinum RTD, 0.00385 alpha curve 1 /2″ NPT male, 316L stainless steel
- All wetted parts are 316L stainless steel
- Spring-loaded probe (thermowell required for spring-loaded versions)
|
| Controls and Functions |
- 4 button front keypad for setup, calibration, and configuration.
- Multi-level user-defined pass codes to prevent unauthorized changes.
- Pass code optional for output test and set point changes.
- Pass code required for configuration and calibration.
|
| Output Test Function |
- Test mode to toggle alarm relays
- Output test function can be pass code protected
|
| Relay Output |
- Two independent SPDT relays 0.5A/115VAC, 1A/24VDC, non-inductive
- Alarm status updated 4 times per second nominal
- Alarm configuration mode can be pass code protected
- Each alarm programmable for either HI or LO set point
- Each alarm programmable for deadband in degrees
- Selectable upscale or downscale burnout
- Selectable normal or reverse alarm action
- Factory defaults: °F temperature scale, SP1 HI, SP2 LO, 1° deadband, downscale burnout, normal alarm action, configuration and test mode not pass code protected.
- 3 ft long, 6-conductor 22 AWG cable for relays
|
| Calibration |
- User settable pass code required to enter calibration mode
- Zero and span temperature calibration
- Non-interactive zero, span, and linearity, ±10% of range
|
| Power |
- 8 to 24 VAC 50/60 Hz or 9 to 32 VDC
- Reverse polarity protected
- 3 ft long, 2-conductor 22 AWG cable for power
|
| Weight |
- Product: 12 ounces (approximately)
- Shipping: 1 pound (approximately)
|
| Housing Materials |
ABS/polycarbonate NEMA 4X case, rear gasket, polycarbonate label, aluminum sensor block |
| Storage Temperature |
40 to 203°F (40 to 95°C) |
| Operating Range |
4 to 185°F (20 to 85°C) at housing |
| Cable Length |
12″ |