Home » Shop » hot sale » Absolute Process Instruments APD 7500 _ transmitter. Fully isolated.

Absolute Process Instruments APD 7500 _ transmitter. Fully isolated.

Original price was: $351.20.Current price is: $270.91.

Sale!

58 in stock

SKU: APD 7500 Category:

Absolute Process Instruments APD 7500 _ transmitter. Fully isolated.

Cecomp Electronics, APD 7500, DC to Frequency Transmitter, 85-265 VAC, 60-300 VDC Power

Features:

  • 24 Selectable Inputs and 30 Selectable Outputs
  • Setup via Rotary Switches and Easy-to-use Tables
  • Zero and Span Output Calibration Potentiometers
  • 1200 V Full Isolation Input/Output/Power
  • Adjustable Low Frequency Cutout
  • Input and Output LoopTracker® LEDs
  • Functional Test Push Button

Applications:

  • Analog to Frequency for Totalizers and Counters
  • Use With APD 7580 for Remote Monitoring

The APD 7500 accepts a DC voltage or current input and provides an optically isolated frequency output that is directly proportional to the input. Common applications include pulse counting or totalizing of DC process signals from devices such as flow transmitters, analog signal transmission over long distances, or analog inputs into PLCs. The full 3-way (input, output, power) isolation makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

A low frequency cutout potentiometer can be adjusted to disable the output when the input falls below a pre-determined level. The APD 7500 can be field-configured via external rotary and slide switches. Common ranges are on the module label, however, virtually unlimited combinations are possible.

The APD 7500 has an open drain MOSFET (open collector) output which requires a user supplied external power supply and pull-up resistor allowing the module to be interfaced with a wide variety of devices. To convert the output to a powered TTL output, simply jumper terminals 1 and 2.

Sink/Source Versatility

For maximum versatility the input can be selectively wired for sinking (unpowered) or sourcing (powered) milliamp output. The 13 VDC loop excitation supply can be used to power a milliamp current loop if required. The input can also be wired for an externally powered loop.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Output Test

An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of the output span. The output test button greatly aids in saving time during initial startup and/or troubleshooting.

Specifications Table:

Input 0-50 mV to ±10 VDC, 0-1 mA to 4-20 mA (Field rangeable voltage or milliamps)
Outputs Field rangeable 0-100 Hz to 0-30 kHz
DC Input Ranges
  • Voltage: 0-50 mVDC to ±10 VDC
  • Current: 0-1 mADC to 0-20 mADC, 4-20 mA
Input Impedance
  • Voltage: 1 MΩ minimum
  • Current: 50 Ω typical
Input Loop Power Supply 13 VDC nominal, regulated, 25 mADC, max. ripple <10 mVp-p (May be selectively wired for sinking or sourcing mA input)
Frequency Output Ranges Switch selectable

  • Low range – Minimum: 0-100 Hz, Maximum: Hz 0-1500, Increments: 100 Hz
  • High range – Minimum: 0-2 kHz, Maximum: 0-30 kHz, Increments: 2 kHz
Output Waveform and Logic Square wave, 50% duty cycle. Normal acting, output increases with increasing input
Output Drivers
  • MOSFET output: open drain, 24 VDC maximum
  • Isink 50 mA maximum
  • Von 0.6 V maximum at 50 mA Isink
  • TTL output: Jumper terminals 1 and 2
  • TTL voltage: 1 to 12 Vp-p depending on load
Cutout Controls
  • Low cutout: Disables output if input is below low cutout level, potentiometer adj. 2% to 25% of range
  • High cutout: Disables output above 120% of output span

Red output LED blinks if either cutout level is near trip point

Output Calibration Multi-turn non-interactive zero and span potentiometers

  • Zero: ±15% of selected span typical
  • Span: “50 to +20% of selected span typical
Output Test/Override Front momentary button or external contact closure sets output to test level. Potentiometer adjustable 0-100% of span.
Linearity Better than ±0.4% of span
Ambient Temperature Range and Stability
  • “10°C to +60°C operating ambient
  • Better than ±0.02% of span per °C stability
Response Time 70 milliseconds nominal
Isolation
  • 1200 VRMS minimum
  • Full isolation: power to input, power to output, input to output
Installation Environment
  • IP 40, requires installation in panel or enclosure
  • For use in Pollution Degree 2 Environment
  • Mount vertically to a 35 mm DIN rail
Connectors Four 4-terminal removable connectors, 14 AWG max wire size
Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 2.5 W maximum